83" 3 Door Reach-In Freezer – 66.5 Cu. Ft.

SKU: SL83F

Price:
Sale price$3,999.00
Product Highlights
66.46 Cu. Ft. Frozen Storage
3 Solid Doors
Forced-Air Refrigeration
Commercial Freezer Storage
115 V / 60 Hz Electrical Supply
AvailabilityNo confirmed local stock
Lead TimeContact for availability
Delivery TimeEstimate upon confirmation
Shipping AreaLos Angeles area
Specifications

General

Model SL83F
Overall Dimensions 82.68 × 31.50 × 80.71 in 2100 × 800 × 2050 mm
Capacity 66.46 cu. ft. 1882 L
Net Weight 507.1 lb 230.0 kg

Refrigeration

Cooling Type Forced-air cooling
Refrigerant R290

Electrical & Construction

Voltage / Frequency 115 V / 60 Hz
Power 785 W
Plug Type NEMA 5-15P
Energy Consumption 10.681 kWh/24h
Certifications ETL Safety; ETL Sanitation

Product Configuration

Doors 3
Shelves 9
Shelf Size Side: 614 × 618 mm; center: 690 × 618 mm
Shelf Load 66.1 lb (30 kg) per shelf

Description

Key Features

01FROZEN-FOOD ACCESS

3 Solid Doors for Frozen Stock

Three solid doors provide separate openings for everyday frozen-food access.

3 solid doors
Read details

The three solid doors support multiple access points across the cabinet for everyday freezer restocking.

03SHELF ORGANIZATION

9 Shelves for Frozen Inventory

Nine specified shelves support organizing frozen goods; each is rated 66.1 lb (30 kg).

9 shelves 66.1 lb / shelf
Read details

Each of the nine specified shelves is rated for 66.1 lb (30 kg). The listed side and center shelf dimensions differ; check shelf position when planning container fit.

05EVERYDAY USE

201 Stainless Steel Interior

The listed 201 stainless steel interior supports routine wipe-downs.

201 stainless interior
Read details

Follow the owner's manual for cleaning methods suitable for the listed 201 stainless steel interior.

06INSTALLATION READINESS

Kitchen Positioning & Cleaning

The specified 4-inch casters help position the cabinet for installation and cleaning.

4-inch casters
Read details

The product listing includes 4-inch casters with locking units. Confirm floor conditions, movement path and manufacturer's handling guidance.

02RATED CAPACITY

66.46 Cu. Ft. Frozen Storage

66.46 cu. ft. (1882 L) of rated freezer storage for kitchen stock.

RATED CAPACITY66.46cu. ft.
Read details

Rated volume is not a validated count of food boxes. Actual fit depends on usable shelf dimensions and required airflow clearance.

04FROZEN FOOD STORAGE

Forced-Air Freezer Cooling

Forced-air refrigeration for a commercial reach-in freezer.

Forced-air cooling
Read details

The product listing confirms forced-air cooling. The model-specific freezer temperature range must be verified on the product nameplate or factory documentation before any exact temperature claim is made.

Shipping, Returns & Warranty

Shipping & Delivery

Delivery areas, estimated transit times and receiving requirements.

View Shipping Policy →

Returns & Refunds

Return eligibility, damaged shipments, refunds and applicable conditions.

View Return & Refund Policy →

Warranty

1-year parts and authorized labor. Compressor coverage totals 3 years from delivery, including Year 1. Years 2–3 cover eligible replacement compressor parts only; labor and related service costs are excluded. Terms apply.

View Warranty Policy →

Need Warranty Assistance?

Email our team with your model, order information and photos. We will review the request and explain the next steps.

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed

Frequently Asked Questions

Quick answers to common questions about this product.

Use & Operating Conditions

Can I put hot food directly into the reach-in?

No. Reach-ins are designed to hold food that is already refrigerated or frozen. They are not designed to quickly cool hot food. Cool hot food in a blast chiller before placing it in the unit.

What room conditions are required for reliable operation?

Keep the room temperature below 32°C (90°F) and relative humidity below 60%. Higher temperature or humidity may reduce cooling performance and may affect warranty coverage.

Will the reach-in fit through a standard doorway?

Compare the unit dimensions with every doorway, hallway, and turn on the delivery path. Check the spec sheet for the exact dimensions.

Handling: Do not transport the unit tilted or with the doors facing the floor.

Measure the full delivery path before ordering to make sure the unit can reach the installation area.

Loading, Doors & Electrical

How should I load the shelves for proper airflow?

Do not overload the shelves. Leave space around products and keep the supply and return air vents clear so cold air can circulate.

Do the doors self-close and stay open at 90°?

Yes. The doors stay open at 90° for easier loading and self-close when opened less than 90°.

What electrical connection does the reach-in require?

Electrical requirements vary by model. Check the product specifications and the unit nameplate for the exact voltage, amperage, plug configuration, and circuit requirements. If any electrical detail is unclear, confirm it with a qualified electrician before installation.

Cleaning, Drainage & Maintenance

How often should I clean the condenser, drain system, shelves, and door gaskets?

Condenser: Clean every 1–3 months.

Drain pan / drain line: Inspect and clean monthly to prevent clogs.

Shelves: Clean weekly or as needed.

Door gaskets: Inspect and wipe clean monthly.

Does the reach-in need a floor drain?

It depends on the model. Some models use automatic condensate evaporation; others require an external drain connection.