72" 6 Door Dual-Zone Reach-In Freezer – 40.1 Cu. Ft.

SKU: Q1.6L6-C

Price:
Sale price$3,299.00
Product Highlights
40.1 Cu. Ft. Large-Capacity Freezer
Two Independently Controlled Freezer Zones
Dual Compressors & Refrigeration Systems
Six-Door Upright Design
Stainless Steel Interior & Exterior
Ships from LAIn stock
Lead TimeIn-stock processing
Delivery Time2–8 business days
Shipping AreaLos Angeles area
Specifications

General

Model Q1.6L6-C
Overall Dimensions 71.65 × 27.56 × 75.98 in 1820 × 700 × 1930 mm
Capacity 40.1 cu. ft. 1136 L
Net Weight 474.0 lb 215 kg

Refrigeration

Temperature Range -0.4~21.2°F -18~-6°C
Cooling Type Direct cooling
Refrigerant R290

Electrical & Construction

Voltage / Frequency 115 V / 60 Hz
Power 507 W
Energy Consumption 7.39 kWh/24h

Product Configuration

Doors 6
Shelves 6 shelves
Shelf Load 66.1 lb 30 kg

Description

Key Features

01DUAL-ZONE FROZEN STORAGE

Two Independent Freezer Zones

Store frozen ingredients in two separately controlled freezer zones within one cabinet.

2 freezer zones Independent control
Read details

The Q1.6L6-C has two independently controlled freezer zones. Operators can use separate settings for different groups of frozen inventory. Both zones are freezer compartments—not a refrigerator/freezer combination.

03CONVENIENT LOADING & ACCESS

Six Self-Closing Doors for Easier Access

Self-closing doors support everyday access, while the stay-open position beyond 90° helps during loading and unloading.

Self-closing doors Stay-open beyond 90°
Read details

The product specification describes six solid self-closing doors that can stay open beyond 90° to make loading and unloading more convenient. Confirm the exact door behavior on the production unit and follow the owner's manual.

05TWO-ZONE CONTROL

Independent Temperature Settings

Adjust the two freezer zones separately within the listed −0.4°F to 21.2°F (−18°C to −6°C) range.

−18°C to −6°C Separate settings
Read details

Both compartments are intended for freezer operation. Their separate temperature controls can be adjusted to suit appropriate frozen inventory needs within the specified operating range. Verify actual holding temperatures and food-safety requirements for each application.

06KITCHEN WORKFLOW

Built for Daily Commercial Use

Six access doors, stainless steel interior and mobile cabinet design support everyday frozen-stock handling.

201 stainless interior 6 × 5-inch casters
Read details

The product specification lists a 201 stainless steel interior, six 5-inch casters and six doors. Together with the separate freezer zones, this supports practical organization and movement for installation and cleaning. Follow the manual for safe operation and installation clearances.

02INDEPENDENT REFRIGERATION

Dual Compressors & Cooling Systems

Each freezer zone has its own compressor and refrigeration system for separate operation.

Two refrigeration systems Direct cooling
COMPRESSORS2independent systems
Read details

Two compressors support two independent refrigeration circuits and electronic temperature controls. This configuration offers more flexibility in freezer management; it does not by itself establish lower energy consumption or guaranteed operation after a component failure.

04CAPACITY & SHELVING

40.1 Cu. Ft. Organized Frozen Storage

40.1 cu. ft. (1136 L) of rated freezer capacity with six shelves for organized frozen inventory.

6 shelves 66.1 lb / shelf
RATED CAPACITY40.1cu. ft.
Read details

Use the six specified shelves to sort frozen ingredients by category and kitchen workflow. Each shelf is listed with a 66.1 lb (30 kg) load rating. Actual package fit depends on usable shelf space and proper loading clearances.

Application

Shipping, Returns & Warranty

Shipping & Delivery

Delivery areas, estimated transit times and receiving requirements.

View Shipping Policy →

Returns & Refunds

Return eligibility, damaged shipments, refunds and applicable conditions.

View Return & Refund Policy →

Warranty

1-year parts and authorized labor. Compressor coverage totals 3 years from delivery, including Year 1. Years 2–3 cover eligible replacement compressor parts only; labor and related service costs are excluded. Terms apply.

View Warranty Policy →

Need Warranty Assistance?

Email our team with your model, order information and photos. We will review the request and explain the next steps.

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed

Frequently Asked Questions

Quick answers to common questions about this product.

Use & Operating Conditions

Can I put hot food directly into the reach-in?

No. Reach-ins are designed to hold food that is already refrigerated or frozen. They are not designed to quickly cool hot food. Cool hot food in a blast chiller before placing it in the unit.

What room conditions are required for reliable operation?

Keep the room temperature below 32°C (90°F) and relative humidity below 60%. Higher temperature or humidity may reduce cooling performance and may affect warranty coverage.

Will the reach-in fit through a standard doorway?

Compare the unit dimensions with every doorway, hallway, and turn on the delivery path. Check the spec sheet for the exact dimensions.

Handling: Do not transport the unit tilted or with the doors facing the floor.

Measure the full delivery path before ordering to make sure the unit can reach the installation area.

Loading, Doors & Electrical

How should I load the shelves for proper airflow?

Do not overload the shelves. Leave space around products and keep the supply and return air vents clear so cold air can circulate.

Do the doors self-close and stay open at 90°?

Yes. The doors stay open at 90° for easier loading and self-close when opened less than 90°.

What electrical connection does the reach-in require?

Electrical requirements vary by model. Check the product specifications and the unit nameplate for the exact voltage, amperage, plug configuration, and circuit requirements. If any electrical detail is unclear, confirm it with a qualified electrician before installation.

Cleaning, Drainage & Maintenance

How often should I clean the condenser, drain system, shelves, and door gaskets?

Condenser: Clean every 1–3 months.

Drain pan / drain line: Inspect and clean monthly to prevent clogs.

Shelves: Clean weekly or as needed.

Door gaskets: Inspect and wipe clean monthly.

Does the reach-in need a floor drain?

It depends on the model. Some models use automatic condensate evaporation; others require an external drain connection.