54" 2 Door Glass Door Merchandiser – 41.3 Cu. Ft.

SKU: GLD54R

Price:
Sale price$2,399.00
Product Highlights
More Even Cooling — Forced-air circulation distributes chilled air across the display.
Plan Energy Costs — Specified energy use: 4.77 kWh per 24 hours.
41.3 Cu. Ft. Storage — Room for a varied beverage selection.
Flexible Shelving — 8 adjustable shelves, rated up to 77.2 lb each.
Insulated Glass Doors — Product visibility with reduced heat transfer.
AvailabilityNo confirmed local stock
Lead TimeContact for availability
Delivery TimeEstimate upon confirmation
Shipping AreaLos Angeles area
Specifications

General

Model GLD54R
Overall Dimensions 54.33 × 31.50 × 80.71 in 1380 × 800 × 2050 mm
Capacity 41.3 cu. ft. 1170 L
Net Weight 463 lb 210.0 kg

Refrigeration

Temperature Range 32~50°F 0~10°C
Cooling Type Forced-air cooling
Refrigerant R290

Electrical & Construction

Voltage / Frequency 115 V / 60 Hz
Power 610 W
Amps 6.3 A
Plug Type NEMA 5-15P
Energy Consumption 4.77 kWh/24h
Certifications ETL Safety + Sanitation

Installation

Minimum Rear Clearance 3.94 in 100 mm
Minimum Side Clearance 3.94 in 100 mm

Product Configuration

Doors 2
Glass Type Double-pane tempered insulated glass
Shelves 4 levels / 8 shelves
Shelf Size 24.15 × 22.32 in 613.5 × 567 mm
Shelf Load 77.2 lb 35 kg
Compressor Location Bottom Mounted

Description

Key Features

01COOLING PERFORMANCE

Cooling That Reaches Across the Display

Forced-air circulation helps distribute chilled air across multiple shelf levels.

Read details

In a multi-shelf beverage cabinet, cooling must reach products beyond the area nearest the refrigeration unit. Forced-air circulation helps distribute chilled air throughout the GLD54R, supporting more even refrigerated conditions between storage areas.

03COOLING & ENERGY USE

Keep the Cold In. Manage Energy Use.

Insulated walls and double-pane glass help keep warm air out, while circulating cold air keeps drinks chilled throughout the cabinet.

Fan-Assisted Airflow Double-Pane Glass 45 mm Foam Insulation
SPECIFIED ENERGY USE4.77kWh / 24h
Read details

Keeping drinks cold is not just about a powerful compressor. It is also about limiting the heat that gets into the cabinet. The GLD54R uses insulated walls and double-pane glass doors to help reduce heat entering the refrigerator. Fans circulate chilled air across the shelves, while temperature controls regulate cooling. Its specified energy consumption is 4.77 kWh per 24 hours, giving you a practical number to help estimate electricity costs. Actual use depends on room temperature, door openings, loading and settings.

05STORAGE & MERCHANDISING

Make Better Use of Every Shelf

Eight adjustable shelves accommodate different bottles and cans.

Read details

Different bottles and cans require different amounts of room. Adjustable shelves let staff group popular beverages by type, change spacing for taller packages and make restocking easier. Check shelf dimensions and individual shelf-load limits when planning the assortment.

06REFRIGERANT TECHNOLOGY

R290 Refrigerant with Lower Climate Impact

R290 offers low global warming potential compared with many older refrigerants.

LOW GWP
Read details

R290 has a low global warming potential compared with many older refrigerants. Refrigerant choice is worth considering alongside equipment energy use and cooling performance; it does not by itself prove lower electricity consumption.

Learn about R290 refrigerant, safety, energy use, and servicing requirements →
02GLASS & INSULATION

Clear Display. Better Insulation.

Read details

Double-pane tempered glass keeps drinks visible while helping limit heat transfer through the doors. Glass-door merchandising helps shoppers see the drinks before opening the cabinet. The GLD54R's double-pane tempered insulated glass provides an additional barrier to heat transfer compared with a single pane. Actual insulation performance depends on the complete door assembly and operating conditions.

Applications

Shipping, Returns & Warranty

Shipping & Delivery

Delivery areas, estimated transit times and receiving requirements.

View Shipping Policy →

Returns & Refunds

Return eligibility, damaged shipments, refunds and applicable conditions.

View Return & Refund Policy →

Warranty

1-year parts and authorized labor. Compressor coverage totals 3 years from delivery, including Year 1. Years 2–3 cover eligible replacement compressor parts only; labor and related service costs are excluded. Terms apply.

View Warranty Policy →

Resources & Downloads

VISUAL TEST ONLY · Unpublished theme

Sample document covers. The Spec Sheet and Manual covers are labeled LG-960M2WP, while this test product is GLD54R. Not approved product documents.

Spec Sheet sample cover
Spec Sheet
PDF 3 Pages
Download PDF
User Manual sample cover
User Manual
PDF 40 Pages
Download PDF
Warranty sample cover
Warranty
PDF 1 Page
Download PDF

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed

Frequently Asked Questions

Quick answers to common questions about this product.

Installation & Electrical

What room temperature and humidity does the unit require?

For reliable operation, keep the room temperature below 32°C and relative humidity (RH) below 60%.

How much clearance does the unit need for ventilation?

Ventilation clearance is model-specific. Use the installation instructions and specification sheet for the exact model rather than applying a single clearance measurement to every merchandiser.

What plug does this unit use? Does it need a dedicated circuit?

Plug type and circuit requirements are model-specific. Check the product specifications and the unit nameplate before ordering or installation. Do not assume every merchandiser uses the same plug or circuit.

Doors, Glass & Shelves

Do the glass doors self-close? Can they stay open or be reversed?

Yes. The doors stay open at 90° and self-close when opened less than 90°. The door swing is factory-set and cannot be reversed on site.

Are the shelves adjustable?

Yes. The shelves are height-adjustable. Stay within the stated shelf load limit and keep the supply and return air vents clear.

Cleaning & Maintenance

How should I clean and maintain the unit?

Condenser: Every 1–3 months, remove dust with a soft brush or vacuum. Do not spray or rinse the condenser directly with water.

Drain / evaporation pan: Empty standing water regularly and clean with a mild detergent to help prevent algae, bacteria, and clogged drains.

Shelves: Remove and wash with warm water and a mild detergent. Do not use abrasive cleaners or steel wool.

Glass: Use a mild glass cleaner and a soft cloth. Avoid ammonia, alcohol, and abrasive cleaners, which may damage the Low-E coating.

Door gaskets: Wipe with warm water and a mild detergent. Check for cracks or wear, and keep the gaskets clean and flexible.

Delivery & Inspection

Do I need liftgate service?

If your delivery location does not have a forklift or loading dock, request liftgate service when ordering. Without a liftgate, the driver generally will not lower the unit from the truck for you.

What should I check when the unit arrives?

Inspect the outer packaging for visible damage before the driver leaves.

Check for signs that the unit was severely tilted during transit. Tilting the unit more than 45° may affect compressor oil return.

If you find damage, note it on the delivery receipt, take clear photos, and contact the supplier or manufacturer within 48 hours so your freight claim is not affected.