40" 2 Door Glass Door Merchandiser – 28.3 Cu. Ft.

SKU: LG-800M2WP

Price:
Sale price$1,899.00
Product Highlights
28.3 Cu. Ft. Display Capacity
Double-Pane Glass Doors
4 Levels, 8 Shelves
Forced-Air Cooling
Electronic Temperature Control
Ships from LAIn stock
Lead TimeIn-stock processing
Delivery Time2–8 business days
Shipping AreaLos Angeles area
Specifications

General

Model LG-800M2WP
Overall Dimensions 39.37 × 28.35 × 78.74 in 1000 × 720 × 2000 mm
Capacity 28.3 cu. ft. 800 L
Net Weight 286.6 lb 130 kg

Refrigeration

Temperature Range 32~50°F 0~10°C
Cooling Type Forced-air cooling
Refrigerant R290

Electrical & Construction

Voltage / Frequency 115 V / 60 Hz
Power 500 W
Energy Consumption 4.02 kWh/24h

Product Configuration

Doors 2
Shelves 4 levels / 8 shelves
Shelf Load 44.1 lb 20 kg

Description

Key Features

01SLIM DESIGN

Slim, Space-Saving Footprint

A 39.37-inch-wide cabinet with a 28.35-inch depth makes it easier to plan refrigerated displays where floor space is limited.

28.35 in depth
28.35
Read details

Overall dimensions: 39.37 × 28.35 × 78.74 in (1000 × 720 × 2000 mm). Measure the installation opening, door swing, access route and required ventilation clearance before ordering.

03MERCHANDISING

Clear Two-Door Display

Double-pane glass doors keep beverage and packaged-product selections visible to customers.

2 glass doors
Read details

The two-door glass-front design helps customers view the assortment without opening the cabinet. Merchandise visibility depends on shelf arrangement and installed lighting; no unverified lighting claims are included.

05STORAGE

Organized 8-Shelf Capacity

28.3 cu. ft. of refrigerated display space arranged across four levels and eight shelves.

8 shelves
CAPACITY28.3cu. ft.
Read details

Four levels and eight shelves support grouping packaged products by category or size. Published shelf load: 44.1 lb (20 kg) per shelf; verify shelf placement and product dimensions for the planned assortment.

06COOLING PERFORMANCE

Forced-Air Cooling

Forced-air cooling and electronic temperature control support refrigerated display operation from 32–50°F (0–10°C).

32–50°F
Read details

The cabinet uses forced-air refrigeration with an electronic controller. Actual product temperatures vary with ambient conditions, loading and door use. Follow installation and operating instructions.

04DAY-TO-DAY USE

Made for Daily Store Operations

An electronic temperature controller and 2-inch swivel and locking casters support everyday adjustment and positioning.

Electronic control 2 in casters
Read details

Use the electronic controller to set the operating temperature. Two-inch casters include swivel and locking types to assist positioning; verify level placement, ventilation, and access before stocking.

Applications

Shipping, Returns & Warranty

Shipping & Delivery

Delivery areas, estimated transit times and receiving requirements.

View Shipping Policy →

Returns & Refunds

Return eligibility, damaged shipments, refunds and applicable conditions.

View Return & Refund Policy →

Warranty

1-year parts and authorized labor. Compressor coverage totals 3 years from delivery, including Year 1. Years 2–3 cover eligible replacement compressor parts only; labor and related service costs are excluded. Terms apply.

View Warranty Policy →

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed

Frequently Asked Questions

Quick answers to common questions about this product.

Installation & Electrical

What room temperature and humidity does the unit require?

For reliable operation, keep the room temperature below 32°C and relative humidity (RH) below 60%.

How much clearance does the unit need for ventilation?

Ventilation clearance is model-specific. Use the installation instructions and specification sheet for the exact model rather than applying a single clearance measurement to every merchandiser.

What plug does this unit use? Does it need a dedicated circuit?

Plug type and circuit requirements are model-specific. Check the product specifications and the unit nameplate before ordering or installation. Do not assume every merchandiser uses the same plug or circuit.

Doors, Glass & Shelves

Do the glass doors self-close? Can they stay open or be reversed?

Yes. The doors stay open at 90° and self-close when opened less than 90°. The door swing is factory-set and cannot be reversed on site.

Are the shelves adjustable?

Yes. The shelves are height-adjustable. Stay within the stated shelf load limit and keep the supply and return air vents clear.

Cleaning & Maintenance

How should I clean and maintain the unit?

Condenser: Every 1–3 months, remove dust with a soft brush or vacuum. Do not spray or rinse the condenser directly with water.

Drain / evaporation pan: Empty standing water regularly and clean with a mild detergent to help prevent algae, bacteria, and clogged drains.

Shelves: Remove and wash with warm water and a mild detergent. Do not use abrasive cleaners or steel wool.

Glass: Use a mild glass cleaner and a soft cloth. Avoid ammonia, alcohol, and abrasive cleaners, which may damage the Low-E coating.

Door gaskets: Wipe with warm water and a mild detergent. Check for cracks or wear, and keep the gaskets clean and flexible.

Delivery & Inspection

Do I need liftgate service?

If your delivery location does not have a forklift or loading dock, request liftgate service when ordering. Without a liftgate, the driver generally will not lower the unit from the truck for you.

What should I check when the unit arrives?

Inspect the outer packaging for visible damage before the driver leaves.

Check for signs that the unit was severely tilted during transit. Tilting the unit more than 45° may affect compressor oil return.

If you find damage, note it on the delivery receipt, take clear photos, and contact the supplier or manufacturer within 48 hours so your freight claim is not affected.